CEDRAL-PIL-EPO-ENG 1/4 13/03/08 CEDRAL Product Information Leaflet 1 1. Product composition CEDRAL consists of: " Portland cement " Mineral fillers " Natural organic reinforcing fibers " Additives " Water-based acrylic dispersion or colorless water repellent impregnation on the face. 2.
Production method CEDRAL is a medium density fiber cement product, manufactured on a Hatscheck machine and autoclaved. The face has a wood grain texture. CEDRAL is then finished either with an acrylic paint or a water repellent impregnation.
3. Dimensions and tolerances " Thickness : 10 mm (on special request, 8 mm thick panels are available) " Dimensions : 190x3600 mm Tolerance Thickness +/- 10% Length +/- 5.0 mm Width +/- 1.5 mm 4. Weight 11.2 kg/piece in standard length 5.
Colours 2 CEDRAL has a wood grain texture and is available in the natural beige colour (uncoated) and a range of standard colours. Please consult the most recent colour chart for the available standard colours. Other colors are available on request in minimum quantities.
Uncoated CEDRAL (S00) is characterized by natural hues in the planks. 1 This product information leaflet replaces any previous editions. EURO PANELS OVERSEAS reserves the right to amend this information leaflet without prior notice.
Readers should always make sure to ... more.
less.
consult the most recent version of this document. 2 See the most recent colour chart for an illustration of the colours. CEDRAL-PIL-EPO-ENG 2/4 13/03/08 6.<br><br> Technical properties (average values) Density : 1300 kg/m³ Bending strength 3 (air dry) // : 23.0 N/mm² Modulus of elasticity // : 7500 N/mm² Maximum water absorption : 35 % Moisture movement (30-90%, mean) : 2.1 mm/m Thermal expansion coefficient : 10*10 -6 m/mK Thermal conductivity coefficient : 0.19 W/mK Frost resistance : frost resistant Reaction to fire according to EN13501-1 : A2 CEDRAL meets the requirements of the European Norm EN 12467 and is CE-marked. 7. Advantages " No flame spread, no fume development, no toxic gasses " Resistant to high temperatures " Water resistant " Resistant to fungae, bacteria, insects, vermin, etc.<br><br> " Resistant to many chemicals " Environmentally friendly, no harmful gas emissions " Frost resistant " High dimensional stability " Can be worked with wood processing machinery and tools " Can be screwed and nailed without pre-drilling " Very little maintenance in comparison to wood CEDRAL because of its fiber cement composition " Aesthetic surface in different colours 8. Applications (not exhaustive) 4 (see also application guidelines for certain applications) Exterior wall cladding, lining of gable ends, dormer windows, roof verges 3 A safety factor should be applied whenever permissible loads are calculated. 4 The applications for CEDRAL set out in this document are for illustration only.<br><br> If in any doubt regarding the suitability of CEDRAL in any given application, it is advisable to request recommendations from EURO PANELS OVERSEAS. Under no circumstances can EURO PANELS OVERSEAS be held liable for applications which have not been approved by EURO PANELS OVERSEAS. CEDRAL-PIL-EPO-ENG 3/4 13/03/08 9.<br><br> Working guidelines (see also working guidelines EURO PANELS OVERSEAS flat sheets) Cutting: " Crosscut saw, slow rotation with tungsten carbide-tipped blade or fast rotation with diamond cutting blade without teeth " Jigsaw with tungsten carbide-tipped cutting blade " Hand saw with tungsten carbide-tipped cutting blade Edge finish : " Fine emery cloth or sanding block " Plane with tungsten carbide tipped blade Drilling : " For holes: tungsten carbide-tipped drill bit (or complete drill in tungsten carbide) with a 60° nose angle. Drilling without hammer!! " For circular openings: hole saw or circular cutter, tungsten carbide-tipped.<br><br> The CEDRAL should be supported around the hole to be drilled (e.g. by a wooden board). !<br><br> Cutting and drilling must take place in a dry environment. All dust must be removed immediately from the CEDRAL with a dry towel to avoid permanent stains. Fixing accessories: Copper accessories should not be used for fixing CEDRAL.<br><br> The material of the fixing accessories (e.g. stainless steel, galvanized steel, phosphated steel) is chosen dependent on the application and the environment. 1) Gluing (concealed fixing): CEDRAL cannot be glued for exterior applications.<br><br> 2) Screwing: Screws with countersunk head, milling wings on the head and special drilling point. Can be screwed directly without pre-drilling. Automatic screwing is also possible.<br><br> 3) Nailing: Automatic or manual nailing with nails with flat head and ringed shank. Can be nailed directly without pre-drilling. The head of the nail should not be driven into the CEDRAL.<br><br> Caulking: Only use neutral mastics. Non-neutral silicones or thiokols can result in staining. CEDRAL-PIL-EPO-ENG 4/4 13/03/08 Touching up: On request, touch-up paint can be supplied.<br><br> Coating: CEDRAL S00 can be finished with a primer and topcoat for exterior use with water-based acrylic finish. When repainting CEDRAL it must first be sanded slightly before applying a new topcoat. Coating advice is available from EURO PANELS OVERSEAS.<br><br> Health and safety aspects : While the CEDRAL is being processed, dust can be released which can irritate airways and eyes. It is recommended that a dust mask and safety goggles be worn. Appropriate dust extraction or proper ventilation should be used depending on the room in which the work is being carried out or the equipment being used.<br><br> Long-term exposure to dust can be harmful to health. 10. Maintenance and cleaning (see also cleaning advice EURO PANELS OVERSEAS flat sheets) For minor soiling, washing with a mild household detergent or soft soap solution followed by rinsing with clear water.<br><br> 11. Handling (see also working guidelines EURO PANELS OVERSEAS flat sheets) CEDRAL is packed on pallets. They must be kept dry during transport.<br><br> CEDRAL must be horizontally stacked on a flat surface. CEDRAL must always be sufficiently supported so that it does not sag. CEDRAL must be stored in a dry ventilated space.<br><br> If CEDRAL is stored outside, it must always be protected against rain by a tarpaulin or plastic sheet. If CEDRAL does become wet in the packing, all packaging must be removed and CEDRAL must be wiped dry and placed in a way that it can dry completely. CEDRAL must be turned on its side before it is lifted up vertically.<br><br> 12. Guarantee The guarantee and the guarantee conditions are available on request from EURO PANELS EURO PANELS OVERSEAS N.V. Bormstraat 22, B-2830 Willebroek - BELGIUM Tel 0032 15 71 82 80 - Fax 0032 15 71 82 89 E-mail: info@europanels.be Website: www.europanels.be VAT BE 0466.056.888 - Bank: KBC 482-9098051-96<br><br>