PART I: GENERAL Work Included: Interior liner fabric of the color specified, support strapping of the appropriate color, fasteners of the appropriate type and color, sealants, thermal break materials and thermal insulation of the appropriate type to insulate the roof and wall areas to the full designed R-value of the building as specified. The installed liner system shall also provide the following OSHA required compliances to save and protect all contractors, workers, inspectors, owners and other individu- als (29 CFR-1926.751 cControlling Contractors d) from injury, penalty and liability, without added cost: A. cThrough fall protection d (29 CFR-1926.501, 1926.760) B.
cProtection from falling objects d (29 CFR-1926.759) C. cProtection from falls through roof openings d (29 CFR-1926.759) D. cProduct-related project safety training d (29 CFR-1926.761) E.
cProduct-related project specific safety plan d (29 CFR-1926.752) Quality Assurance: Provide the materials in original man- ufacturer 9s packages together with detailed instructions and project drawings of the installation. Materials shall be inspect- ed for damage, proper sizes and quantities upon delivery and stored in a dry, secure manner. Post the detailed train- ing instructions, project specific safety drawings, and plans for OSHA compliance using the product.
Installation shall proceed with care to assure proper ... more.
less.
sealing of the liner fabric. Insulation shall be placed on (roof) or behind (walls) the liner fabric in the full-specified thickness without voids or compres- sion. Notify Thermal Design (800-255-0776) immediately of any damages, improper sizes or shortages.<br><br> No changes or substitutions will be allowed unless submitted at least 10 days prior to bid date and in compliance with Simple Saver System standards as set forth in this specification. Substitutions of systems that do not have a continuous vapor barrier on the inside plane of the purlins or girts will not be allowed. Purlins, girts and insulation must be completely isolated from the inside conditioned air with an effective vapor barrier.<br><br> Taping or stapling of vapor barrier lap joints is not acceptable. Sealing field joints with a permanent vapor barrier lap sealant is required. Field seams, if any, shall be made on a structural member and mechanically attached with a metal band and fasteners along its full length.<br><br> All exposed parts of the system shall be Class A material and have flame spread of 25 or less based on ASTM E84 stan- dards. Vapor barrier fabric shall be white or colored woven coated fabric with opaque light-gray back and triple extrusion- welded seams fabricated in one piece, to fit not less than the full bay length by the width of the building. Buildings more than 100´ wide may have field seams on the bottom of a purlin but no less than 50´ apart.<br><br> Any field seams must be sealed with vapor barrier lap sealant. Wall bay minimum fabric size shall be not less than one entire wall bay or end wall column space from the ceiling to the floor. Perimeter edges of the vapor barrier fabric shall be trimmed and sealed to the adjoining steel or fabric with vapor barrier lap sealant.<br><br> All edges of liner fabric, including field seams, shall be mechanically fastened with steel retaining straps the full perimeter. In the event that the crew is not experienced in the installation procedures, vid- eotaped or on-site installation training shall be requested by the installing contractor from Thermal Design to assure proper installation procedures. Submittals: Include manufacturer 9s product brochures; com- ponent specifications, samples of the painted support strap- ping, and samples of the Syseal® reinforced polyethylene vapor barrier fabric, including a sample of the extrusion weld- ed seam; specific detailed drawings from Thermal Design for the project showing purlin spacings, support strap locations and spacings, fastening points, liner fabric sizes and loca- tions; insulation widths and thicknesses, sizes and locations and detailed installation instructions for quality assurance and OSHA compliance.<br><br> Safety Compliance Clause: Detailed installation instruc- tions are provided to assure proper installation and func- tion for OSHA safety compliance as an alternative form of fall protection in metal building structures. Fall protection certificate available free of charge from Thermal Design. (U.S.<br><br> Patent #5901518) PART II: PRODUCTS Acceptable systems shall be the Simple Saver insulation sys- tem (with free OSHA Compliant through fall protection) manu- factured by Thermal Design with an installed total roof insula- tion R-value of _____ (R-30 recommended) and an average installed thickness of _______ inches (9 d recommended). Roof system shall be a single- or double-layer system (select one) . A thermal block shall be applied where there is no exist- ing thermal break between metal panel and metal structure.<br><br> The thermal break shall be (select one): 3/16Ý x 3Ý foam tape, 3/8Ý Snap-R® thermal block, or 1Ý Snap-R® thermal block. The installed total insulation R-value of wall insulation shall be R-_____ (R-25 recommended) and an average installed thickness of _____ inches (8Ý recommended). System com- ponents include a ten-year material warranty and shall meet the following minimum specifications: Steel Strap: 100 KSI minimum yield high tensile strength steel, galvanized, primed and then painted the specified color on the exposed side with a clear coat primer on the unexposed side.<br><br> Minimum size shall be 0.02Ý x 1Ý x continuous length. The strap color shall be (select one): UVMAX® 8 White, UVMAX® 8 Silver Aspen or UVMAX® 8 Black. Note: Stainless steel, woven polyester plastic (non-fall protection) and colored SPECIFICATIONS: SIMPLE SAVER SYSTEM® FOR NEW PRE-ENGINEERED METAL BUILDINGS (with Free OSHA Compliant Fall Protection and a Ten-year Limited Material Warranty) MasterFormat" Division 7: Thermal Protection MasterFormat" Division 13: Special Construction, Section 13 34 19 3Metal Building Systems Thermal Design PO Box 468 Madison, NE 68748 (800) 255-0776 www.thermaldesign.com strapping is available on a special order basis.<br><br> Traverse strap pattern shall include one strap six (6) inches away from each rafter flange with the remaining space between rafters divided into equal spaces not to exceed five (5) feet. Longitudinal straps shall be nominally thirty (30) inches on-center, with two adjacent straps at the ridge line. Fasteners: #12 x 3/4Ý, plated self-drilling screws with sealing washers painted to match the specified color for fastening to light gauge steel (up to 12 GA purlins) or #12 x 11D4Ý plated self-drilling screws with sealing washers, painted to match the specified color for heavier gauge steel (up to 3/8Ý purlins/bar joist).<br><br> Special fasteners for wood, concrete and other structure types are available from Thermal Design and should be used when appropriate. Always install two fasteners in the end of each strap for safety and to withstand installation stress, and one fastener at all other designated fastening points. Syseal® Fabric: Shall be woven reinforced high-density poly- ethylene yarns coated on both sides with a continuous white or colored polyethylene film.<br><br> The fabric grade for the roof shall be (select one): Syseal® FP (White), Syseal® SW FP (Super White), Syseal® SA FP (Silver Aspen), or Syseal® BLK FP (Black). The fabric grade for the walls shall be (select one): Syseal® FP, Syseal® SW FP, Syseal® SA FP, or Syseal® BLK FP. The fabric shall comply with UL/ULC 723 or ASTM E84, and be Class A compliant with a low flame spread index of 25 or less based on ASTM E84 test standards.<br><br> This mate- rial shall be manufactured in large custom pieces by extrusion welding from roll goods. Pieces shall be fabricated to substan- tially fit the large defined building areas with minimum practi- cal sealing to be done on job site. Fabric shall be folded to allow for rapid pull-out on the strap support system.<br><br> The fabric shall be certified for free fall protection by the manufacturer. (Custom colors available by special order. Call 800-255-0776 for details.) Liner fabric perm rating shall be (select one) : 0.02 grains per hour per square foot based on ASTM E96, procedure B or liner fabric shall not function as a vapor barrier but shall be perforated with 3/16Ý minimum holes space not more than four inches apart in each direction.<br><br> Sealants: Shall be Simple Saver System G524 high tack solvent-based vapor barrier sealant for sealing vapor barrier laps and/or Syseal® Tape (double-sided bonding tape) 3/4Ý wide by 1/32Ý thick extruded vapor barrier sealant by Thermal Design. Insulation: Shall be formaldehyde-free fiberglass blanket or batt insulation meeting ASTM C991 Type 1, ASTM E136 and ASTM E84 or other insulation form as may be recommended and submitted by the system manufacturer and approved by the architect during submittals. Insulation Hangers: Shall be Fast-R" insulation hangers for supporting insulation between wall girts or roof purlins in roof pitches over 4:12.<br><br> Thermal Break (Block): Thermal break shall be (select one): 1/8Ý thick by 3Ý wide white, closed cell polyethylene foam with pre-applied adhesive film and peel-off backing, 3/8Ý polystyrene Snap-R® thermal block or 1Ý polystyrene Snap- R® thermal block. The selection shall be provided as thermal break where there is no existing thermal break. PART III: EXECUTION Simple Saver Roof System: Cut to length and install painted steel straps in the pattern and spacings as shown on the project shop drawings.<br><br> The straps are installed in tension and span immediately below the bottom plane of the purlins. Position the pre-folded vapor barrier liner fabric on the strap platform along one eave purlin. Clamp the two bottom corners squarely at the eave and centered on the bay.<br><br> Pull the other end of the pleat-folded fabric across the building width on the strap platform but below the purlins, pausing only at the ridge to fasten the straps and fabric into position where the plane of the roof changes. Once positioned, the remaining fasten- ers are installed from the bottom side at each purlin/strap intersection and the edges are sealed and trimmed along the rafters. A similar method can be used starting at the ridge purlin space and pulling the fabric to each eave.<br><br> Insulation is unpacked and placed on the vapor liner system. Shake to the specified thickness. In two-layer systems, the second layer of insulation is placed over and perpendicular to the purlins as the roof sheeting is applied.<br><br> It is important that the insulation cavity be filled or the cavities be ventilated to minimize the probability of condensation. (Ventilated and/or dehumidified roof systems are possible with the Simple Saver System). Call Thermal Design (800-255-0776) for details.<br><br> Simple Saver Wall System: Sheet the building with just the thermal break (if specified) applied to the exterior of the girts. Insulation is cut to the required lengths to fit vertically between the girts and installed in the girt spaces on Fast-R insulation hangers. Fluff the insulation to the specified thickness, mak- ing sure there are no gaps or voids.<br><br> Insulate the complete wall section. Apply the wall vapor barrier fabric by clamping it into position over the eave strap. Once in position, the fasten- ers are installed through the wall straps, eave strap and into each roof strap, permanently clamping the wall fabric between them.<br><br> Seal the wall fabric to the roof fabric, base angle, or base cee channel and on the column flanges. Additional straps are installed along the base angle and each column to retain the system permanently in place. Detailed installation instructions are to be sent along with the project drawings specific for the project and included with the materials in each shipment.<br><br> Pertinent information is included on the drawings for each project. Review all information and instructions prior to commencement. If any questions arise, contact the manufacturer prior to installation.<br><br> On-site installa- tion training is available for actual expense. The manufactur- er 9s toll-free hotline is 800-255-0776. Note: The Simple Saver System with OSHA Compliant through fall protection can be applied to many different structure types and installation execution varies slightly.<br><br> Also, installations and specifications for existing buildings vary. Call or write for specific details. A design manual is also available upon request.<br><br> Shrink-wrap license terms are included on design manuals, installation instructions, video training tapes and compact discs. For more information about the ten-year material warranty, see www.thermaldesign.com/warranty/. United States Patent #5901518.<br><br> Thermal Design is constantly developing and improving its products. We reserve the right to improve and change component specifications without notice. Simple Saver System®, Syseal®, UVMAX® and Snap-R® are registered trademarks of Thermal Design, Inc.<br><br> Copyright © 2010 Thermal Design, Inc. All Rights Reserved. SSS_NewSpecs.indd JA 05/19/10 Printed in U.S.A.<br><br>